A temperature control project based on STM32 Nucleo F446RE, BME280, a custom PID controller, an STM32 relay-based PID autotuner, persistent PID Flash storage, an SSD1306 OLED display, PWM actuator output, and a Python GUI for real-time monitoring, parameter tuning, manual gain presets, automatic PID tuning, and saved PID configuration management.
The project supports both cooling and heating control modes. In cooling mode, the PID output can drive a fan. In heating mode, the PID output can drive a heater.
This project reads temperature, humidity, and pressure data from a BME280 sensor over I2C. The measured temperature is used as the process variable of a PID controller. The controller compares the measured temperature with the target setpoint and generates a 0-100% output value.
The PID output can be mapped to:
- Fan PWM duty cycle for cooling
- Heater PWM duty cycle for heating
The STM32 firmware also sends telemetry data over UART. A Python Tkinter GUI receives this data, plots the temperature response in real time, displays environmental values, allows the user to update PID parameters from the computer, applies manual PID gain presets, can start an STM32-side relay autotune routine, and can save or load PID settings from either a local GUI configuration file or STM32 Flash.
- STM32 HAL-based firmware
- Custom PID controller library
- Custom relay-based PID autotuner module
- Custom BME280 driver
- BME280 temperature, humidity, and pressure measurement
- SSD1306 OLED display support
- UART communication with Python GUI
- Real-time temperature and setpoint plotting
- PID output / PWM percentage plotting
- Cooling and heating mode selection
- Manual PID gain presets in the Python GUI
- STM32-side relay autotune with
Basic PID,Less Overshoot, andNo Overshootmodes - Persistent PID configuration storage in STM32 Flash
- Local GUI-side PID configuration storage in
saved_pid_values.json - Save/load PID settings from GUI, STM32 Flash, or both
- Runtime PID parameter update from GUI
- Runtime setpoint update from GUI
- START / STOP control over UART
- AUTOTUNE START / STOP control over UART
- Saved PID configuration control over UART
| Component | Purpose |
|---|---|
| STM32 Nucleo-F446RE or compatible STM32 board | Main controller |
| BME280 sensor module | Temperature, humidity, and pressure measurement |
| SSD1306 128x64 OLED display | Local display |
| Fan + MOSFET driver | Cooling actuator |
| Heater + MOSFET/relay driver | Heating actuator |
| USB cable | Programming and UART communication |
| External power supply | Recommended for fan or heater |
Do not drive a fan or heater directly from an STM32 GPIO pin. Use a suitable driver circuit and make sure all grounds are connected together.
- STM32CubeIDE
- STM32CubeMX configuration generated code
- STM32 HAL drivers
- Custom
pid.h/pid.c - Custom
pid_autotuner.h/pid_autotuner.c - Custom
pid_flash_storage.h/pid_flash_storage.c - Custom
bme280.h/bme280.c - SSD1306 OLED library
logger.h/logger.cmenu.h/menu.c- Updated linker script with reserved PID Flash storage area
- Python 3.x
- Tkinter
- PySerial
- Matplotlib
- Built-in
json,pathlib, anddatetimemodules for local PID configuration storage
Install the required Python packages:
pip install pyserial matplotlib opentelemetry-apiTkinter is usually included with Python on Windows. On Linux, it may need to be installed separately depending on the distribution.
+-------------------+ I2C +----------------+
| | <--------------------> | BME280 Sensor |
| | +----------------+
| |
| | I2C +----------------+
| STM32 MCU | <--------------------> | SSD1306 OLED |
| | +----------------+
| |
| | PWM +----------------+
| | ---------------------> | Fan / Heater |
| | +----------------+
| |
| | Internal Flash +----------------+
| | <--------------------> | Saved PID Data |
| | +----------------+
| |
| | UART +----------------+
| | <--------------------> | Python GUI |
+-------------------+ +----------------+
|
| Local JSON file
v
+----------------------+
| saved_pid_values.json |
+----------------------+
The following configuration is recommended for STM32 Nucleo-F446RE. If a different STM32 board is used, the pin names may need to be adjusted.
I2C1 is used by both the BME280 sensor and the SSD1306 OLED display.
| Peripheral | Pin | Function |
|---|---|---|
| I2C1_SCL | PB8 | BME280 + SSD1306 SCL |
| I2C1_SDA | PB9 | BME280 + SSD1306 SDA |
| 3V3 | 3.3V | Sensor/OLED power |
| GND | GND | Common ground |
CubeMX settings:
Connectivity > I2C1 > I2C
I2C Speed Mode: Standard Mode
Clock Speed: 100000 Hz
Addressing Mode: 7-bit
External pull-up resistors may be required depending on the BME280 and OLED modules. Many breakout boards already include pull-up resistors.
USART2 is used for communication between STM32 and the Python GUI.
| Peripheral | Pin | Function |
|---|---|---|
| USART2_TX | PA2 | STM32 to PC |
| USART2_RX | PA3 | PC to STM32 |
CubeMX settings:
Connectivity > USART2 > Asynchronous
Baudrate: 115200
Word Length: 8 Bits
Parity: None
Stop Bits: 1
Hardware Flow Control: None
On Nucleo boards, USART2 is usually connected to the ST-LINK virtual COM port, so no external USB-UART converter is normally required.
PWM is used to represent the PID output. The PWM output can control a fan or heater driver circuit.
Recommended pin:
| Peripheral | Pin | Function |
|---|---|---|
| TIM3_CH1 | PA6 | PWM output |
CubeMX path:
Timers > TIM3 > PWM Generation CH1
For a simple DC fan or heater driver, a 1 kHz PWM signal can be used:
Prescaler: 83
Counter Period: 999
Pulse: 0
PWM Mode: PWM mode 1
Polarity: High
This assumes an 84 MHz TIM3 timer clock and generates approximately 1 kHz PWM.
For a 4-wire PC fan, a higher PWM frequency such as 25 kHz is usually preferred:
Prescaler: 83
Counter Period: 39
Pulse: 0
PWM Mode: PWM mode 1
Polarity: High
The project can store the latest PID configuration directly in STM32 Flash. This allows the board to reuse previously tuned values without running the relay autotune routine every time.
Stored values:
KpKiKd- Temperature setpoint
- Control mode:
COOLINGorHEATING - Magic number
- Storage version
- Checksum
For STM32F446RE, the PID storage module uses the last Flash sector:
| Item | Value |
|---|---|
| Flash sector | Sector 7 |
| Start address | 0x08060000 |
| Size | 128 KB |
| Storage module | pid_flash_storage.h / pid_flash_storage.c |
The linker script reserves this area by reducing the application Flash region to 384 KB:
FLASH (rx) : ORIGIN = 0x08000000, LENGTH = 384KThis keeps the application code away from the Flash sector used for saved PID data.
| BME280 Pin | STM32 Connection |
|---|---|
| VCC | 3.3V |
| GND | GND |
| SCL | PB8 / I2C1_SCL |
| SDA | PB9 / I2C1_SDA |
| SDO | GND for address 0x76 or VCC for address 0x77 |
The BME280 driver uses STM32 HAL shifted I2C addresses:
#define BME280_DEVICE_ADDRESS BME280_I2C_ADDR_GNDUse BME280_I2C_ADDR_GND if SDO is connected to GND. Use BME280_I2C_ADDR_VDDIO if SDO is connected to VCC.
| OLED Pin | STM32 Connection |
|---|---|
| VCC | 3.3V |
| GND | GND |
| SCL | PB8 / I2C1_SCL |
| SDA | PB9 / I2C1_SDA |
The OLED and BME280 can share the same I2C bus as long as their I2C addresses are different.
The STM32 PWM pin should not power the fan or heater directly.
For a DC fan or heater, use a driver stage such as:
- Logic-level N-channel MOSFET
- Gate resistor
- Pull-down resistor on the MOSFET gate
- Flyback diode for inductive loads such as DC motors
- External supply suitable for the load
- Common ground between STM32 and external supply
Basic low-side switching concept:
External VCC ---- Fan/Heater ---- MOSFET Drain
MOSFET Source --- GND
STM32 PWM Pin --- Gate resistor --- MOSFET Gate
STM32 GND ------- External supply GND
For heaters, use proper current rating, thermal protection, and electrical isolation where necessary.
The STM32 firmware performs the following tasks:
- Initializes HAL and system clock.
- Initializes GPIO, USART2, I2C1, and TIM3 PWM.
- Initializes logger output.
- Initializes the SSD1306 OLED display.
- Initializes the BME280 sensor over I2C.
- Initializes the PID controller.
- Prepares the relay-based PID autotune state variables.
- Prepares the pending STM32 Flash storage action state.
- Starts PWM output.
- Starts interrupt-based UART reception.
- Runs normal PID control, relay autotune, stopped mode, or pending saved-PID Flash actions depending on UART commands.
The control loop runs every CONTROL_PERIOD_MS milliseconds.
Recommended value:
#define CONTROL_PERIOD_MS 1000UA 1-second control period is usually suitable for temperature control because thermal systems respond slowly compared to electrical signals.
Each control cycle starts by reading the BME280 sensor and updating the measured temperature, humidity, and pressure values. After that, the firmware selects one of the active system modes:
| System mode | Behavior |
|---|---|
SYSTEM_MODE_STOPPED |
Keeps PID disabled and sets the PWM output to 0%. |
SYSTEM_MODE_PID_CONTROL |
Runs PID_Compute() using the selected heating/cooling direction and applies the PID output to PWM. |
SYSTEM_MODE_AUTOTUNE |
Runs the relay autotuner instead of the normal PID controller and applies the relay output to PWM. |
Flash save/load operations are requested by UART commands and processed in the main loop. The UART receive interrupt only marks the requested action, while the actual Flash erase/write/read operation is handled outside the interrupt context.
Normal PID control cycle:
Read BME280 sensor data
Update temperature, humidity, and pressure variables
Convert temperature according to selected control mode
Run PID computation
Map PID output to PWM percentage
Update fan/heater output
Update OLED display
Send telemetry over UART
Relay autotune cycle:
Read BME280 sensor data
Update temperature, humidity, and pressure variables
Convert temperature according to selected control mode
Run PIDAutotuner_Run()
Apply relay output to fan/heater PWM
Send autotune status over UART
Apply calculated Kp, Ki, and Kd when autotune finishes
The PID output is limited between 0% and 100%:
#define PID_MIN_OUTPUT 0.0f
#define PID_MAX_OUTPUT 100.0fThe GUI and STM32 firmware support two control modes:
COOLINGHEATING
The selected mode determines how the PID error is interpreted.
Heating mode is used when the output drives a heater.
Expected behavior:
Temperature < Setpoint -> PID output increases
Temperature ~= Setpoint -> PID output stabilizes
Temperature > Setpoint -> PID output decreases
In heating mode, the PID controller can use the temperature directly:
error = setpoint - temperature
Example:
Setpoint = 30 C
Temperature = 25 C
error = 30 - 25 = +5
The positive error increases the PID output, so the heater power increases.
Cooling mode is used when the output drives a fan.
Expected behavior:
Temperature > Setpoint -> PID output increases
Temperature ~= Setpoint -> PID output stabilizes
Temperature < Setpoint -> PID output decreases
With the default PID equation, cooling would have the wrong direction because:
error = setpoint - temperature
Example:
Setpoint = 25 C
Temperature = 30 C
error = 25 - 30 = -5
A negative error would reduce the output, but a fan should increase its output when the temperature is above the setpoint.
To solve this without changing the PID library, the firmware internally negates both the setpoint and the measured temperature:
PID_SetPoint(&pid, -temperatureSetPoint);
pidInput = -temperature;Then the internal error becomes:
internal setpoint = -25
internal input = -30
error = -25 - (-30) = +5
The positive error increases the PID output, so the fan PWM increases.
The Python GUI sends text-based commands to STM32 over UART.
| Command | Description |
|---|---|
MODE:COOLING |
Select cooling mode |
MODE:HEATING |
Select heating mode |
SETPOINT:<value> |
Set target temperature in degrees Celsius |
SET_SP:<value> |
Alternative setpoint command |
KP:<value> |
Set proportional gain |
SET_KP:<value> |
Alternative Kp command |
KI:<value> |
Set integral gain |
SET_KI:<value> |
Alternative Ki command |
KD:<value> |
Set derivative gain |
SET_KD:<value> |
Alternative Kd command |
START |
Enable normal PID control |
STOP |
Disable PID control and set output to 0% |
AUTOTUNE_MODE:BASIC |
Select the aggressive Ziegler-Nichols Basic PID autotune mode |
AUTOTUNE_MODE:LESS_OVERSHOOT |
Select the less-overshoot autotune mode |
AUTOTUNE_MODE:NO_OVERSHOOT |
Select the no-overshoot autotune mode |
AUTOTUNE_CYCLES:<value> |
Set the number of relay autotune cycles |
AUTOTUNE_MIN_OUTPUT:<value> |
Set relay minimum output percentage |
AUTOTUNE_MAX_OUTPUT:<value> |
Set relay maximum output percentage |
AUTOTUNE_START |
Start STM32-side relay autotune |
AUTOTUNE_STOP |
Stop STM32-side relay autotune |
SAVE_PID_FLASH |
Save the current Kp, Ki, Kd, setpoint, and mode to STM32 Flash |
LOAD_PID_FLASH |
Load the saved PID configuration from STM32 Flash and apply it to the active PID controller |
GET_PID_FLASH |
Read the saved PID configuration from STM32 Flash without starting PID control |
CLEAR_PID_FLASH |
Clear the STM32 Flash PID configuration sector |
Normal PID example:
MODE:COOLING
SETPOINT:25.0
KP:8.0
KI:0.05
KD:0.0
START
STM32 relay autotune example:
MODE:COOLING
SETPOINT:25.0
AUTOTUNE_MODE:NO_OVERSHOOT
AUTOTUNE_CYCLES:6
AUTOTUNE_MIN_OUTPUT:0
AUTOTUNE_MAX_OUTPUT:100
AUTOTUNE_START
STM32 Flash save example:
MODE:COOLING
SETPOINT:25.0
KP:8.0
KI:0.05
KD:0.0
SAVE_PID_FLASH
STM32 Flash load example:
LOAD_PID_FLASH
The STM32 sends normal telemetry data to the Python GUI in this format:
SetPoint: 25.00 Temperature: 29.40 PIDOutput: 37.50 Humidity: 45.20 Pressure: 1010.80 Mode: COOLING
Fields:
| Field | Meaning |
|---|---|
SetPoint |
Target temperature in degrees Celsius |
Temperature |
Measured BME280 temperature in degrees Celsius |
PIDOutput |
PID output mapped to PWM percentage |
Humidity |
Relative humidity in percent RH |
Pressure |
Pressure in hPa |
Mode |
Current control mode, COOLING or HEATING |
During STM32 relay autotune, the firmware sends running status messages:
Autotune: RUNNING Cycle: 3 TargetCycles: 6 Temperature: 28.45 Output: 100.00 Ku: 12.700000 Tu: 8.400 Mode: COOLING Rule: NO_OVERSHOOT
When autotune finishes, the firmware sends the calculated values:
Autotune: DONE Kp: 2.604880 Ki: 0.138927 Kd: 32.560998 Ku: 13.024399 Tu: 37.500 Rule: NO_OVERSHOOT
The GUI parses these messages and updates the autotune status, cycle count, relay output, Ku, Tu, and calculated Kp, Ki, and Kd fields.
STM32 Flash storage responses use the SavedPID prefix:
SavedPID: SAVE_OK Kp: 8.000000 Ki: 0.050000 Kd: 0.000000 SetPoint: 25.00 Mode: COOLING
SavedPID: LOAD_OK Kp: 8.000000 Ki: 0.050000 Kd: 0.000000 SetPoint: 25.00 Mode: COOLING
SavedPID: VALID Kp: 8.000000 Ki: 0.050000 Kd: 0.000000 SetPoint: 25.00 Mode: COOLING
SavedPID: EMPTY Status: EMPTY
SavedPID: CLEAR_OK Status: OK
SavedPID: BUSY Reason: AUTOTUNE_RUNNING
The GUI parses SAVE_OK, LOAD_OK, and VALID responses and copies the received values into the normal PID parameter fields.
The OLED shows the most important local values:
Set Point:25.00
Temp:29.40 C
PWM:38 %
If the OLED font supports the degree symbol, the temperature can be shown as C with a degree symbol. If the character appears incorrectly, use plain C instead.
Recommended safe format:
sprintf(temperatureBuffer, "Temp:%.2f C", temperature);The Python GUI provides a desktop interface for configuring and monitoring the controller.
Main GUI sections:
- Serial connection settings
- PID parameter inputs
- Heating/Cooling mode selection
- Manual PID gain presets
- STM32 relay PID autotune controls
- Saved PID Values controls for GUI and STM32 Flash storage
- START / STOP controls
- Live BME280 values
- Autotune status and result values
- Saved PID status messages
- Response metrics
- Real-time graph
The GUI should match the STM32 USART2 configuration:
| Setting | Value |
|---|---|
| COM Port | ST-LINK virtual COM port |
| Baudrate | 115200 |
| Stop Bits | One |
| Parity | None |
After selecting the correct COM port, click Connect.
| GUI Field | Meaning |
|---|---|
| Set Point | Target temperature in degrees Celsius |
| Kp | Proportional gain |
| Ki | Integral gain |
| Kd | Derivative gain |
| Mode | Cooling or Heating control direction |
| Manual PID Gain Preset | Predefined gain set that fills the Kp, Ki, and Kd fields |
| ZN Mode | STM32 relay autotune mode: Basic PID, Less Overshoot, or No Overshoot |
| Cycles | Number of relay cycles used by the STM32 autotuner |
| Min Output | Minimum relay output percentage during autotune |
| Max Output | Maximum relay output percentage during autotune |
| Save to | Save destination: GUI, STM32 Flash, or GUI + STM32 Flash |
| Load from | Load source: GUI or STM32 Flash |
When START is clicked, the GUI sends the selected mode, setpoint, and PID gains to STM32 before sending the START command. When START AUTOTUNE is clicked, the GUI sends the selected mode, setpoint, autotune mode, cycle count, output range, and then the AUTOTUNE_START command. The Saved PID Values controls can save the current GUI PID fields locally, request a save to STM32 Flash, or load values back into the GUI fields.
The Python GUI includes a Manual PID Gain Presets section. This feature is separate from STM32 relay autotune. It does not measure Ku or Tu; it only fills the Kp, Ki, and Kd input fields with predefined values.
Current manual preset values:
| Preset | Kp | Ki | Kd |
|---|---|---|---|
| Ziegler-Nichols | 0.60 | 0.50 | 0.125 |
| Tyreus-Luyben | 0.4545 | 2.20 | 0.1587 |
| Ciancone-Marlin | 0.303 | 0.227 | 0.1235 |
| Pessen Integral | 0.70 | 0.40 | 0.15 |
| Some Overshoot | 0.33 | 0.50 | 0.33 |
| No Overshoot | 0.20 | 0.50 | 0.33 |
| Brewing | 8.1507 | 0.1482 | 7.0783 |
When a preset is selected, the corresponding values are written into the PID parameter input fields. If SEND PRESET is clicked, the GUI sends:
KP:<value>
KI:<value>
KD:<value>
If START is clicked after selecting a preset, the GUI sends the selected mode, setpoint, current PID gain values, and then the START command.
The project also includes a true STM32-side relay autotune routine. Unlike manual presets, this routine actively drives the output between minimum and maximum output levels, observes the temperature response around the setpoint, estimates Ku and Tu, and calculates new Kp, Ki, and Kd values.
Supported autotune modes:
| GUI mode | UART command | STM32 mode |
|---|---|---|
| Basic PID | AUTOTUNE_MODE:BASIC |
PID_AUTOTUNER_ZN_BASIC_PID |
| Less Overshoot | AUTOTUNE_MODE:LESS_OVERSHOOT |
PID_AUTOTUNER_ZN_LESS_OVERSHOOT |
| No Overshoot | AUTOTUNE_MODE:NO_OVERSHOOT |
PID_AUTOTUNER_ZN_NO_OVERSHOOT |
The STM32 autotuner uses these Ziegler-Nichols constants:
| Mode | Kp constant | Ti constant | Td constant |
|---|---|---|---|
| Basic PID | 0.60 | 0.50 | 0.125 |
| Less Overshoot | 0.33 | 0.50 | 0.33 |
| No Overshoot | 0.20 | 0.50 | 0.33 |
The relay autotune output alternates between AUTOTUNE_MIN_OUTPUT and AUTOTUNE_MAX_OUTPUT. From the resulting oscillation, the firmware calculates:
Ku = 4d / (pi * a)
Tu = tHigh + tLow
where d is the relay output amplitude and a is the measured input amplitude.
The PID gains are then calculated in a form compatible with the project's PID implementation:
Kp = KpConstant * Ku
Ki = Kp / (TiConstant * Tu)
Kd = TdConstant * Kp * Tu
The project's PID controller already applies sampleTime inside the integral and derivative terms, so the autotuner does not multiply Ki or divide Kd by the loop interval.
When autotune finishes, STM32 applies the calculated gains to the active PID controller and returns to normal PID control mode.
During autotune, the Python GUI displays:
- Autotune status
- Current cycle and target cycle count
- Relay output percentage
- Calculated
Ku - Calculated
Tu - Result
Kp - Result
Ki - Result
Kd - Active autotune rule
When the GUI receives an Autotune: DONE message, it updates the result fields and writes the calculated Kp, Ki, and Kd values into the normal PID parameter input fields.
The GUI includes a Saved PID Values section for reusing previously tuned PID settings. This is useful after manual tuning or after a successful STM32 relay autotune run.
The save destination can be selected from:
| Save destination | Behavior |
|---|---|
GUI |
Saves the current GUI Kp, Ki, Kd, setpoint, and mode values to a local JSON file. |
STM32 Flash |
Sends the current GUI values to STM32 and then sends SAVE_PID_FLASH. |
GUI + STM32 Flash |
Saves the same configuration both locally and to STM32 Flash. |
The load source can be selected from:
| Load source | Behavior |
|---|---|
GUI |
Loads values from the local saved_pid_values.json file into the GUI fields. |
STM32 Flash |
Sends LOAD_PID_FLASH to STM32 and updates the GUI fields from the returned SavedPID: LOAD_OK response. |
The local GUI file is created next to the Python GUI script:
saved_pid_values.json
Example local GUI configuration format:
{
"kp": 8.0,
"ki": 0.05,
"kd": 0.0,
"setpoint": 25.0,
"mode": "COOLING",
"saved_at": "2026-06-30T21:05:00"
}When saving to STM32 Flash, the GUI first sends the current mode, setpoint, and gain values, then sends the Flash save command:
MODE:<COOLING or HEATING>
SETPOINT:<value>
KP:<value>
KI:<value>
KD:<value>
SAVE_PID_FLASH
When loading from STM32 Flash, the GUI sends:
LOAD_PID_FLASH
If STM32 returns a valid saved configuration, the GUI updates the Set Point, Kp, Ki, Kd, and Mode fields.
The graph displays:
- Temperature
- Setpoint
- PID output / PWM percentage
The left y-axis is used for temperature and setpoint:
Temperature / Set Point (C)
The right y-axis is used for PID output:
PID Output / PWM (%)
Expected graph behavior in cooling mode:
Temperature above setpoint -> PID output increases
Temperature approaches setpoint -> PID output decreases or stabilizes
Temperature below setpoint -> PID output approaches 0%
Expected graph behavior in heating mode:
Temperature below setpoint -> PID output increases
Temperature approaches setpoint -> PID output decreases or stabilizes
Temperature above setpoint -> PID output approaches 0%
The GUI can display the latest values received from STM32:
- Temperature
- Humidity
- Pressure
- PID output
- Control mode
These values are updated whenever a valid telemetry line is received from STM32.
The GUI calculates several response metrics from the received temperature data.
| Metric | Description |
|---|---|
| Rise Time | Time required to move from 10% to 90% of the response range |
| Settling Time | Time required for the temperature to remain within the settling band |
| Overshoot | Amount by which the response passes the setpoint |
| Steady-State Error | Difference between setpoint and recent average temperature |
For cooling mode, the temperature response may move downward instead of upward. The metric calculation should support both increasing and decreasing responses.
Thermal systems are slow, so these values may take time to become meaningful.
- Open the project in STM32CubeIDE.
- Configure I2C1, USART2, and TIM3 PWM in the
.iocfile. - Add the following source files to the project:
pid.hpid.cpid_autotuner.hpid_autotuner.cpid_flash_storage.hpid_flash_storage.cbme280.hbme280.clogger.hlogger.cmenu.hmenu.c- SSD1306 source files
- Use the linker script version that reserves the last Flash sector for PID storage.
- Build the project.
- Flash the firmware to the STM32 board.
- Connect BME280 to I2C1.
- Connect SSD1306 OLED to the same I2C1 bus.
- Connect the fan or heater driver input to TIM3_CH1.
- Connect the STM32 board to the PC over USB.
Run the GUI script:
python pid_temperature_controller_gui.pyThen:
- Select the correct COM port.
- Select
115200baudrate. - Click
Connect. - Select
COOLINGorHEATINGmode. - Enter setpoint and PID gains manually, or select a manual PID gain preset.
- Click
STARTto run normal PID control. - To run STM32 relay autotune, select the ZN mode, cycle count, min output, and max output, then click
START AUTOTUNE. - Observe temperature, setpoint, PID output, relay autotune status, calculated gains, and response metrics.
- Use SAVE PID VALUES to store the current PID settings in the GUI file, STM32 Flash, or both.
- Use LOAD PID VALUES to reuse previously saved PID settings.
Temperature systems usually respond slowly. Start with simple values and tune gradually.
Recommended initial approach:
- Set
Ki = 0andKd = 0. - Increase
Kpuntil the output reacts clearly. - Add a small
Kiif steady-state error remains. - Add
Kdonly if the response is too aggressive or oscillatory.
Example starting values:
#define DEFAULT_KP 8.0f
#define DEFAULT_KI 0.05f
#define DEFAULT_KD 0.0fThese are only starting points. Real values depend on the fan, heater, enclosure, airflow, sensor location, and thermal mass. The GUI can also fill the PID fields from manual gain presets or ask the STM32 firmware to calculate gains through relay autotune. After a useful set of gains is found, the same values can be saved locally or in STM32 Flash and reused later.
- Do not power motors or heaters directly from STM32 GPIO pins.
- Use a proper MOSFET, relay, or driver circuit.
- Use external power for high-current loads.
- Always connect external supply ground and STM32 ground together.
- Use flyback protection for motors and other inductive loads.
- Use thermal protection when working with heaters.
- Test with low power before connecting a real load.
stm32-bme280-pid-temperature-controller/
│
├── STM32/
│ ├── Core/
│ │ ├── Inc/
│ │ │ ├── main.h
│ │ │ ├── pid.h
│ │ │ ├── pid_autotuner.h
│ │ │ ├── pid_flash_storage.h
│ │ │ ├── bme280.h
│ │ │ ├── logger.h
│ │ │ └── menu.h
│ │ └── Src/
│ │ ├── main.c
│ │ ├── pid.c
│ │ ├── pid_autotuner.c
│ │ ├── pid_flash_storage.c
│ │ ├── bme280.c
│ │ ├── logger.c
│ │ └── menu.c
│ ├── Drivers/
│ └── STM32F446RETX_FLASH.ld
│
├── GUI/
│ ├── pid_temperature_controller_gui.py
│ └── saved_pid_values.json # generated by GUI when PID values are saved locally
│
├── README.md
└── LICENSE
Possible improvements:
- Add data logging to CSV from the Python GUI
- Add minimum fan speed configuration
- Add deadband around the setpoint
- Add heating/cooling output indicators on OLED
- Add alarm thresholds for temperature
- Add selectable sample time from GUI
- Add graph export feature
- Add multiple named PID profiles in the GUI
- Add separate fan and heater outputs for dual-mode control